Product Description
Enclosed AC Disconnect Switch, NEMA 4X (IP65), 100A 600VAC 3 Pole, Yellow Body With Red Rotary , UL508 approved.
Type: AC DisconnectPhase/Poles: 3
Amps: 100
Material: Plastic
Warranty: 1 Year
- Technical Info
- Specifications
- Also Purchased Products
Technical Specifications Technical Datasheet
Data according to IEC 947-3, IEC 947-5-1, VDE 0660, EN 60947-3, EN 60947-5-1
Type |
|
..69..20 |
..69..25 |
..69..32 |
..69..40 |
..69..63 |
..69..80 |
..69..100 |
..69..125 |
||
Main Contacts |
|
|
|
|
|
|
|
|
|||
Rated thermal current Ith open |
A |
20 |
25 |
32 |
40 |
63 |
80 |
100 |
125 |
||
Rated thermal current Ith enclosed |
A |
20 |
25 |
32 |
40 |
63 |
80 |
100 |
110 |
||
Rated insulation voltage Ui 1) |
V |
690 |
690 |
690 |
690 |
690 |
690 |
1000 |
1000 |
||
Rated operational current Ie AC21A |
A |
20 |
25 |
32 |
40 |
63 |
80 |
100 |
125 |
||
Making capacity Ieff |
3x380-440V |
A |
160 |
190 |
220 |
300 |
370 |
440 |
725 |
850 |
|
Breaking capacity |
3x220-240V |
A |
160 |
180 |
200 |
250 |
330 |
380 |
580 |
680 |
|
|
3x380-440V |
A |
160 |
180 |
200 |
250 |
330 |
380 |
580 |
680 |
|
|
3x660-690V |
A |
80 |
110 |
140 |
170 |
190 |
220 |
330 |
420 |
|
Disconnection property performed up to |
V |
690 |
690 |
690 |
690 |
690 |
690 |
1000 |
1000 |
||
Motor switch AC3 |
3x400V |
A |
12 |
16 |
23 |
30 |
37 |
37 |
60 |
72 |
|
Motor switch AC3 |
3x220-240V |
kW |
3 |
4 |
5.5 |
7.5 |
11 |
11 |
18.5 |
22 |
|
Direct switching of single motors |
3x380-440V |
kW |
5.5 |
7.5 |
11 |
15 |
18.5 |
18.5 |
30 |
37 |
|
|
|
3x660-690V |
kW |
5.5 |
7.5 |
11 |
15 |
18.5 |
18.5 |
22 |
30 |
Main switch |
AC23 |
3x400V |
A |
16 |
20 |
25 |
32 |
45 |
45 |
72 |
85 |
Motor switch |
AC23A |
3x220-240V |
kW |
4 |
5.5 |
7.5 |
9 |
15 |
15 |
22 |
30 |
Main switch |
AC23B |
3x380-440V |
kW |
7.5 |
10 |
12.5 |
16 |
22 |
22 |
37 |
45 |
Safety switch |
|
3x660-690V |
kW |
5.5 |
7.5 |
11 |
15 |
18.5 |
18.5 |
30 |
37 |
Rated conditional short-circuit current |
kAeff |
10 |
10 |
10 |
10 |
10 |
10 |
10 |
5 |
||
Max. fuse size gL (gG) |
A |
25 |
35 |
40 |
40 |
63 |
80 |
100 |
125 |
||
Mechanical life |
x103 |
200 |
200 |
200 |
200 |
100 |
100 |
100 |
100 |
||
Rated short-time wihstand current (1 sec. current) |
A |
250 |
300 |
400 |
500 |
600 |
850 |
1200 |
1500 |
||
Power loss per pole AC21 = Ith |
|
|
|
|
|
|
|
|
|
||
P/pole [W] |
|
PM, SH |
0.322 |
0.503 |
0.824 |
1.288 |
2.739 |
4.416 |
5.330 |
8.328 |
|
|
|
LB, DM, PE |
0.364 |
0.569 |
0.933 |
1.458 |
2.739 |
4.416 |
5.330 |
8.328 |
|
R/pole [mΩ] |
|
PM, SH |
0.805 |
0.805 |
0.805 |
0.805 |
0.690 |
0.690 |
0.533 |
0.533 |
|
|
|
LB, DM, PE |
0.911 |
0.911 |
0.911 |
0.911 |
0.690 |
0.690 |
0.533 |
0.533 |
|
Cable cross sections |
|
mm2 |
|
0.5 - 10 |
|
1 - |
25 |
4 - |
50 |
||
solid or stranded |
|
AWG |
|
20 - 8 (10) |
|
16 - |
3 (10) |
10 - 0 |
0 (10) |
||
flexible |
|
mm2 |
|
0.5 - 6 |
|
4 - |
16 |
10 |
35 |
||
|
|
AWG |
|
20 - 10 |
|
16 |
- 6 |
8 |
2 |
||
flexible (+ multicore cable end) |
|
mm2 |
|
0.5 - 6 |
|
0.75 |
- 16 |
6 - |
35 |
||
|
|
AWG |
|
20 - 10 |
|
16 |
- 6 |
8 |
2 |
||
Size of terminal screw |
|
|
|
M3.5 |
|
|
M5 |
|
M6 |
||
Tightening torque |
|
Nm |
|
1.7 - 2.3 |
|
2.8 |
- 4 |
1.7 |
- 4.5 |
||
Auxiliary contacts |
|
|
|
|
|
|
|
|
|
||
Rated insulation voltage Ui 1) |
|
V |
|
|
6 |
90 |
|
|
|
||
Rated thermal current Ith, ithe |
|
A |
|
|
1 |
0 |
|
|
|
||
Switching capacity AC15 |
220-240V |
A |
|
|
2 |
.5 |
|
|
|
||
AC15 |
380-440V |
A |
|
|
1 |
.5 |
|
|
|
||
Rated conditional short-circuit current |
|
kAeff |
|
|
3 |
|
|
|
|
||
Max. short circuit protection |
gL (gG) |
A |
|
|
1 |
0 |
|
|
|
||
Cable cross sections |
|
mm2 |
|
|
0.75 |
- 2.5 |
|
|
|
||
Solid or stranded |
|
AWG |
|
|
14 |
12 |
|
|
|
||
Flexible (+ multicore cable end) |
|
mm2 |
|
|
0.75 - |
2.5 (1.5) |
|
|
|
||
|
|
AWG |
|
|
18 |
14 |
|
|
|
||
Data according to UL and cUL |
|
|
|
|
|
|
|
|
|
||
Rated voltage |
|
V |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
600 |
|
Ampere rating “General Use” |
|
A |
20 |
25 |
32 |
40 |
63 |
80 |
100 |
125 |
|
DOL rating 3-phase |
110 - 120V |
HP |
1 |
1.5 |
2 |
2 |
3 |
5 |
10 |
15 |
|
|
220 - 240V |
HP |
3 |
5 |
5 |
5 |
10 |
10 |
25 |
30 |
|
|
440 - 480V |
HP |
7.5 |
10 |
10 |
10 |
20 |
20 |
50 |
60 |
|
|
550 - 600V |
HP |
10 |
10 |
15 |
15 |
25 |
25 |
60 |
60 |
|
DOL rating 1-phase |
110 - 120V |
HP |
1 |
1 |
1 |
1 |
2 |
2 |
5 |
7.5 |
|
|
200 - 208V |
HP |
1 |
2 |
2 |
2 |
3 |
3 |
10 |
10 |
|
|
220 - 240V |
HP |
2 |
2 |
3 |
3 |
5 |
5 |
15 |
15 |
|
Fuse size (RK5) Manual motor controller |
A |
40 |
50 |
50 |
70 |
90 |
110 |
125 |
125 |
||
5kA / 600V Motor disconnect |
A |
40 |
50 |
50 |
50 |
70 |
70 |
125 |
125 |
||
Tightening torque |
Nm |
|
1.7 - 2.3 |
|
2.8 - 4 |
1.7 - 4.5 |
|||||
|
lb.inch |
|
11 - 20 |
|
24 - 35 |
15 - 40 |
1) Suitable for: earthed-neutral systems, overvoltage category I to III, pollution degree 3 (standard-industry): Uimp = 6kV. Data for other conditions on request 2) The values after the slash are valid for switches 6-pole or more
- Suitable for no load application (A20A) above 690V
- Fuse RK1 / 10kA / 600V
- Uimp = 8kV
Model Number | Short Description | Sale Price | QTY | Stock Status | Lead Time | Specs | |
---|---|---|---|---|---|---|---|